Details
Our products cover energy storage systems, thermal management systems, fire protection systems, EMS systems, and inverter systems.
Description
We use standard chassis and containers that can flexibly match system energy according to customer needs. Our products cover energy storage systems, thermal management systems, fire protection systems, EMS systems, and inverter systems.
Features
Safe and reliable.
BMS three-level architecture.
Cloud scheduling.
Supports cloud scheduling for economical operation.
Efficient conversion.
System efficiency reaches 88%.
Flexible system configuration.
Supports multi-machine parallel function.
DC parameters |
||
Cell type |
Prismatic/3.2V 280Ah |
LiFePO4 Battery |
Nominal capacity |
2.365 MWh |
704V 280Ah*12 |
Voltage range |
638V~770V |
Cell: 2.8~3.55V |
Battery system efficiency |
≥98% |
Capacity efficiency |
Communication |
CAN, Modbus RTU |
|
AC parameters |
||
AC Rated Power |
500kWA *2 (2 in Parallel) |
|
AC Max. Power |
500kWA *2 (2 in Parallel) |
|
System efficiency |
≥88% |
|
Rated AC Voltage |
400V |
|
Grid voltage range |
±10% |
|
Power factor |
>0.99 |
|
Power factor adjustable range |
1 (lead) ~ 1 (lag) |
|
Rated frequency |
50 Hz/60 Hz |
|
Grid frequency range |
±20% |
|
AC current distortion rate |
<3% |
|
DC component
|
<0.5% |
|
EPS-AC |
Three-phase three-wire system + ground wire |
3W+PE |
System Parameters |
||
Operating temperature |
5~30℃ |
Industrial temperature control air conditioning |
IP Grade |
IP54 |
|
Environment temperature |
-30℃~50℃ |
|
RH |
0~95% |
|
Noise |
<70dB |
|
Man-machine interaction |
Touch LCD screen +EMS background |
|
Seismic grade |
Ⅶ |
|
Communication |
RS485, Ethernet |
|
Communication protocol |
Modbus RTU, Modbus TCP |
|
Containers overall external dimensions |
40HQ/12.192*2.438*2.896m |
|
Containers internal dimensions |
40HQ/12.032*2.352*2.698 |